STR.RM1 - Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms

The following models are available:

STR.RM1.L.HC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Low-Rise, High-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Low-Rise Building with 1-3 stories.
Design Level Approximate Basis:
Post-1975 construction in UBC Seismic Zone 4, NEHRP Map Area 7.

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.L.LC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Low-Rise, Low-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Low-Rise Building with 1-3 stories.
Design Level Approximate Basis:
1941-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5
Post-1941 construction in UBC Seismic Zone 2A, NEHRP Map Area 4
Post-1975 construction in UBC Seismic Zone 1, NEHRP Map Area 2/3

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.L.MC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Low-Rise, Moderate-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Low-Rise Building with 1-3 stories.
Design Level Approximate Basis:
Post-1941 construction in UBC Seismic Zone 3, NEHRP Map Area 6
Post-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5.

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.L.PC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Low-Rise, Pre-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Low-Rise Building with 1-3 stories.
Design Level: Approximate Basis: UBC Seismic Zone 0, NEHRP Map Area 1.
Pre-1941 construction in all other UBC and NEHRP areas.
Pre-Code damage functions are appropriate for modeling older buildings that were not designed for earthquake load, regardless of where they are located in the United States.

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.M.HC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Mid-Rise, High-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Mid-Rise Building with 4-7 stories.
Design Level Approximate Basis:
Post-1975 construction in UBC Seismic Zone 4, NEHRP Map Area 7.

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.M.LC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Mid-Rise, Low-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Mid-Rise Building with 4-7 stories.
Design Level Approximate Basis:
1941-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5
Post-1941 construction in UBC Seismic Zone 2A, NEHRP Map Area 4
Post-1975 construction in UBC Seismic Zone 1, NEHRP Map Area 2/3

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.M.MC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Mid-Rise, Moderate-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Mid-Rise Building with 4-7 stories.
Design Level Approximate Basis:
Post-1941 construction in UBC Seismic Zone 3, NEHRP Map Area 6
Post-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5.

Suggested Block Size: 1 EA (round up to integer quantity)


STR.RM1.M.PC | Structural, Reinforced Masonry Bearing Walls with Wood or Metal Deck Diaphragms, Mid-Rise, Pre-Code

Structural components represent the structural system in the building.
Structural System: These buildings have perimeter bearing walls of reinforced brick or concrete-block masonry. These walls are the vertical elements in the lateral force-resisting system. The floors and roof are framed with wood joists and beams either with plywood or braced sheathing, the latter either straight or diagonally sheathed, or with steel beams with metal deck with or without concrete fill. Interior wood posts or steel columns support wood floor framing; steel columns support steel beams.
Mid-Rise Building with 4-7 stories.
Design Level: Approximate Basis: UBC Seismic Zone 0, NEHRP Map Area 1.
Pre-1941 construction in all other UBC and NEHRP areas.
Pre-Code damage functions are appropriate for modeling older buildings that were not designed for earthquake load, regardless of where they are located in the United States.

Suggested Block Size: 1 EA (round up to integer quantity)