FEMA P-58 2nd Edition
The models in this dataset are based on the 2nd edition of FEMA P-58. Specifically, the parameters are parsed from the FEMAP-58_FragilityDatabase_v3.1.2.xls file that is published as part of Volume 3 of the methodology. A few obvious typos and errors have been fixed in that file; these adjustments are captured in the changelog at https://github.com/NHERI-SimCenter/DB_DamageAndLoss/blob/main/data_sources/FEMA_P58/changelog.txt . Simultaneous damage states have been replaced with equivalent Mutually exclusive damage states. Component classification is based on UNIFORMAT II as per NISTIR 6389.
- B - Shell
- B.10 - Super Structure
- B.10.31 - Steel Columns
- B.10.33 - Steel Braces
- B.10.35 - Steel Connections
- B.10.41 - RC or Composite Columns
- B.10.42 - RC or Composite Beams
- B.10.44 - RC or Composite Shearwalls
- B.10.49 - RC Flat Slabs
- B.10.51 - Ordinary Reinforced Masonry Walls
- B.10.52 - Special Reinforced Masonry Walls
- B.10.61 - Cold-formed Steel Walls
- B.10.71 - Wood Light Frame
- B.20 - Exterior Enclosure
- B.30 - Roofing
- B.10 - Super Structure
- C - Interiors
- D - Services
- E - Equipments and furnishings
- F - Special Construction & Demolition