STR.W1 - Wood, Light Frame
The following models are available:
STR.W1.HC | Structural, Wood, Light Frame, High-Code
Structural components represent the structural system in the building.
Structural System: These are typically single-family or small, multi-family dwellings of not more than 5,000 square feet of floor area and 1-2 stories. The essential structural feature of these buildings is repetitive framing by wood rafters or joists on wood stud walls. Loads are light and spans are small. These buildings may have relatively heavy masonry chimneys and may be partially or fully covered with masonry veneer. Most of these buildings, especially the single-family residences, are not engineered but constructed in accordance with “conventional construction” provisions of building codes. Hence, they usually have the components of a lateral-force-resisting system even though it may be incomplete. Lateral loads are transferred by diaphragms to shear walls. The diaphragms are roof panels and floors that may be sheathed with sawn lumber, plywood or fiberboard sheathing. Shear walls are sheathed with boards, stucco, plaster, plywood, gypsum board, particle board, or fiberboard, or interior partition walls sheathed with plaster or gypsum board.
Design Level Approximate Basis:
Post-1975 construction in UBC Seismic Zone 4, NEHRP Map Area 7.
Suggested Block Size: 1 EA (round up to integer quantity)
STR.W1.LC | Structural, Wood, Light Frame, Low-Code
Structural components represent the structural system in the building.
Structural System: These are typically single-family or small, multi-family dwellings of not more than 5,000 square feet of floor area and 1-2 stories. The essential structural feature of these buildings is repetitive framing by wood rafters or joists on wood stud walls. Loads are light and spans are small. These buildings may have relatively heavy masonry chimneys and may be partially or fully covered with masonry veneer. Most of these buildings, especially the single-family residences, are not engineered but constructed in accordance with “conventional construction” provisions of building codes. Hence, they usually have the components of a lateral-force-resisting system even though it may be incomplete. Lateral loads are transferred by diaphragms to shear walls. The diaphragms are roof panels and floors that may be sheathed with sawn lumber, plywood or fiberboard sheathing. Shear walls are sheathed with boards, stucco, plaster, plywood, gypsum board, particle board, or fiberboard, or interior partition walls sheathed with plaster or gypsum board.
Design Level Approximate Basis:
1941-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5
Post-1941 construction in UBC Seismic Zone 2A, NEHRP Map Area 4
Post-1975 construction in UBC Seismic Zone 1, NEHRP Map Area 2/3
Suggested Block Size: 1 EA (round up to integer quantity)
STR.W1.MC | Structural, Wood, Light Frame, Moderate-Code
Structural components represent the structural system in the building.
Structural System: These are typically single-family or small, multi-family dwellings of not more than 5,000 square feet of floor area and 1-2 stories. The essential structural feature of these buildings is repetitive framing by wood rafters or joists on wood stud walls. Loads are light and spans are small. These buildings may have relatively heavy masonry chimneys and may be partially or fully covered with masonry veneer. Most of these buildings, especially the single-family residences, are not engineered but constructed in accordance with “conventional construction” provisions of building codes. Hence, they usually have the components of a lateral-force-resisting system even though it may be incomplete. Lateral loads are transferred by diaphragms to shear walls. The diaphragms are roof panels and floors that may be sheathed with sawn lumber, plywood or fiberboard sheathing. Shear walls are sheathed with boards, stucco, plaster, plywood, gypsum board, particle board, or fiberboard, or interior partition walls sheathed with plaster or gypsum board.
Design Level Approximate Basis:
Post-1941 construction in UBC Seismic Zone 3, NEHRP Map Area 6
Post-1975 construction in UBC Seismic Zone 2B, NEHRP Map Area 5.
Suggested Block Size: 1 EA (round up to integer quantity)
STR.W1.PC | Structural, Wood, Light Frame, Pre-Code
Structural components represent the structural system in the building.
Structural System: These are typically single-family or small, multi-family dwellings of not more than 5,000 square feet of floor area and 1-2 stories. The essential structural feature of these buildings is repetitive framing by wood rafters or joists on wood stud walls. Loads are light and spans are small. These buildings may have relatively heavy masonry chimneys and may be partially or fully covered with masonry veneer. Most of these buildings, especially the single-family residences, are not engineered but constructed in accordance with “conventional construction” provisions of building codes. Hence, they usually have the components of a lateral-force-resisting system even though it may be incomplete. Lateral loads are transferred by diaphragms to shear walls. The diaphragms are roof panels and floors that may be sheathed with sawn lumber, plywood or fiberboard sheathing. Shear walls are sheathed with boards, stucco, plaster, plywood, gypsum board, particle board, or fiberboard, or interior partition walls sheathed with plaster or gypsum board.
Design Level: Approximate Basis: UBC Seismic Zone 0, NEHRP Map Area 1.
Pre-1941 construction in all other UBC and NEHRP areas.
Pre-Code damage functions are appropriate for modeling older buildings that were not designed for earthquake load, regardless of where they are located in the United States.
Suggested Block Size: 1 EA (round up to integer quantity)